I am still waiting for the FLI camera and filter wheel, so I am using the H694 from Starlight Xpress for now. I had to get an extra connector from preciseparts from it :-( They aren't cheap, but it so worth it - very stable and robust!
First, I had to focus the scope. Without the Robofocus I had to focus manually. And I could even use my old Bahtinov mask - I bought it for my 6" SCT. And it fits quite well on the TOA 130.
Next, I wanted to adjust the red dot finder. I do remember that this was a major pain in the a... But with SGPro, I could use it's center function to center the scope on a bright star (Deneb) and then adjust the red dot finder until it was over Deneb. Wow - that was easy!
Then I wanted to do some basic curvature analysis. After all, that was one of the main reasons to switch from an SCT to a refractor. Took some random images and analyzed them with CCDInspector:
Not too bad! The remaining tilt could be with the imaging train. I'll investigate this more when I get my FLI camera.
Next on my list was to calibrate SGPro to take flats with my flip-flat. Took me a while to figure that out. But now I have all my filters calibrated. But the flats look like this:
Yikes! Seems like I got a lot of dust into the imaging train when I assembled it. Will fix that with the new camera too.
At some point when the scope pointed almost straight up, guiding became VERY shaky. Pretty much unusable. When I checked the scope, I noticed that the filter wheel was hitting the Mach1 keypad - which was dangling loosely. See these image that I took the next day:
Seems like I will have to move all the cables and everything to the front or back to the scope. This is certainly a problem that I didn't have with the shorter EDGE scope before.
Finally, I took some images just to see how they look like:
This is a simple Luminance image (10 subs a 10 minutes) of M31. Only stacked no processing whatsoever. Very impressed with the amount of detail that I can see here. Can't wait to take some real images!!!
Astrophotography combines some of my major passions in life: mathematics, astronomy, computers ... and buying gadgets!
Saturday, December 14, 2013
Sunday, November 24, 2013
New Scope #2 - Cabling
I had to order 2 more counterweights to mount the Takahashi scope (it's so much heavier then the Celestron EDGE scope!) Once I had those, I could work on mounting it and connecting it. I wanted to move all the equipment boxes (Robofocus box, Dew Heater box, Power distribution, USB hub). Then I only have 2 cables through the mount which should make this easier. Also, when moving the scope outside or back, I would have to carry the mount and the scope separately - and that would be much easier if I only have to connect 2 cables.
Went to Home Tepot to buy fitting screws and some metal sheets. I screwed them into the bottom of the accessory ring:
And then mounted all boxes on the side with velcro tape:
The metal is a little too flimsy and bends slightly. Either I have to buy thicker sheets or alternatively I could try to 3D print a perfectly fitting piece. But for now, all boxes are now on the scope - and they are on the axis, i.e. don't contribute too much to the momentum of the scope.
When I used the scope, I noticed that I couldn't pull out the focuser enough - the cables were too tights. Of course, with this focuser I have to leave some slack in the cables:
I never had that issue with the Schmidt-Cassegrain scope ...
Went to Home Tepot to buy fitting screws and some metal sheets. I screwed them into the bottom of the accessory ring:
And then mounted all boxes on the side with velcro tape:
The metal is a little too flimsy and bends slightly. Either I have to buy thicker sheets or alternatively I could try to 3D print a perfectly fitting piece. But for now, all boxes are now on the scope - and they are on the axis, i.e. don't contribute too much to the momentum of the scope.
When I used the scope, I noticed that I couldn't pull out the focuser enough - the cables were too tights. Of course, with this focuser I have to leave some slack in the cables:
I never had that issue with the Schmidt-Cassegrain scope ...
Friday, November 15, 2013
New Scope #1
I finally decided to get a new scope. There are too many issues with the Celestron EDGE to make it a fully-automated imaging platform with minimum maintenance. After a very long search, I finally decided to get a 130NFB Takahashi refractor. Together with a FLI 11002-2 MLI camera, larger filters, filter wheel, OAG and other necessary equipment (new mounting plate, clamshell, red dot finder, Robofocus bracket...) A BIG thanks to Chris Hendren from Opt Telescopes. He and I exchanged countless emails to figure out which scope and equipment I need. He never got tired of helping me to understand different scopes and equipment and how I could integrate them.
While I was on a business trip, I found this scope (with a Scope Guard case, clamshell and an accessory ring) on Astromart. I bought it and on my return the shipped scope was waiting for me. I also bought all the other equipment from Opt Telescopes (plus the Robofocus bracket from Technical Innovations and Flip Flat panels from Optec) - unfortunately it will take a little while until all of it arrives.
When I came home, the new scope was waiting for me. So, well packaged! I took it out and the first thing I noticed was how big and heavy this beauty is. From the pictures, you don't really get this. And also how BIG a 4" focuser is!
First thing I did was to install the Robofocus bracket, so that I can use my Robofocus unit with the Rack&Pinion focuser. Took me a little while to figure out how.
1. Had to remove one of the focus knobs
and then install the bracket on the focuser with the Robofocus motor on top.
The bigest problem was how to remove the wheel from my Celestron focuser that was on the motor shaft:
I emailed Jeremy from Technical Innovations Robofocus and he offered to remove it for me. So, I sent it off...
But I could put the red dot finder on the scope. I mounted it to the focuser:
Although I might want to move it to the accessory ring too - it's made out of metal, i.e. not super light weight. And the less weight I have at the end of the scope the better. But for now I can use it.
While I was on a business trip, I found this scope (with a Scope Guard case, clamshell and an accessory ring) on Astromart. I bought it and on my return the shipped scope was waiting for me. I also bought all the other equipment from Opt Telescopes (plus the Robofocus bracket from Technical Innovations and Flip Flat panels from Optec) - unfortunately it will take a little while until all of it arrives.
When I came home, the new scope was waiting for me. So, well packaged! I took it out and the first thing I noticed was how big and heavy this beauty is. From the pictures, you don't really get this. And also how BIG a 4" focuser is!
(see my feet on the left hand side, to get an idea of the size!)
First thing I did was to install the Robofocus bracket, so that I can use my Robofocus unit with the Rack&Pinion focuser. Took me a little while to figure out how.
1. Had to remove one of the focus knobs
and then install the bracket on the focuser with the Robofocus motor on top.
The bigest problem was how to remove the wheel from my Celestron focuser that was on the motor shaft:
I emailed Jeremy from Technical Innovations Robofocus and he offered to remove it for me. So, I sent it off...
But I could put the red dot finder on the scope. I mounted it to the focuser:
Although I might want to move it to the accessory ring too - it's made out of metal, i.e. not super light weight. And the less weight I have at the end of the scope the better. But for now I can use it.
Sunday, October 13, 2013
Collimation and imaging train tilt
After the CalStar desaster, I decided to try to improve focus, collimation and imaging tilt.
First, I wanted to improve collimation. In order to remove as many sources of errors as possible, I started just with eyepieces.
1. Visual
First using the 40mm eyepiece and then the 4mm, I collimated to scope as good as possible out of focus. Seeing wasn't great - when I tried to use in-focus collimation, I could hardly see any Airy disk.
2. Camera directly on scope
I removed the focal reducer, spacers, filter wheel, OAG. I couldn't get the scope to focus anymore, but that was OK. I used CCDInspector's out-of-focus collimation. I used ΞΆ Cygni - it was very high up and has no other bright stars around it. Used 30 sec exposures to minimize atmospheric and other distortions. And always waited at least 3 images with similar errors.
I started with a 16" collimation error! I turned the camera around to make sure that the error that I'm seeing is purely the scope and not the camera. Moved it slowly down to 4". Then it changed direction. And then it got funny: for the other 2 collimation screws, the star moved away from the screw when I tightened it. But for the third, it moved towards the screw when I tightened it. That certainly explains the difficulties that I had to improve collimation earlier. After I figured this out, I could bring collimation below 1" (then it changed direction from picture to picture).
Also, at this point the image had no tilt at all!
Now I could have slowly added equipment to it.
... but instead, I'd rather focus on Hyperstar imaging. I know now that the camera is completely orthogonal, so I can use it for collimation of the Hyperstar lens. So, reconfigure the entire scope (cables, secondary mirror, hyperstar lens).
Collimating the Hyperstar lens turns out to be a major pain in the ...
I have to use multi-star collimation - because of the wide field of the Hyperstar lens, I couldn't find a brigh enough start that didn't have other stars in its vicinity. Furthermore, to defocus a start enough for out-of focus collimation with CCDInspector is outside of the range of my focuser!
Because of stray light and the moon light, I have to use a shield on the scope to get correct collimation. But that means that I have to take the damn shield off whenever I need to adjust the Hyperstar lens, then put it back on.
This is the initial state:
This is the final result:
Almost no collimation: good!
Almost no image tile: good!
But look at that curvature!!! I have absolutely no idea what to do about that...
First, I wanted to improve collimation. In order to remove as many sources of errors as possible, I started just with eyepieces.
1. Visual
First using the 40mm eyepiece and then the 4mm, I collimated to scope as good as possible out of focus. Seeing wasn't great - when I tried to use in-focus collimation, I could hardly see any Airy disk.
2. Camera directly on scope
I removed the focal reducer, spacers, filter wheel, OAG. I couldn't get the scope to focus anymore, but that was OK. I used CCDInspector's out-of-focus collimation. I used ΞΆ Cygni - it was very high up and has no other bright stars around it. Used 30 sec exposures to minimize atmospheric and other distortions. And always waited at least 3 images with similar errors.
I started with a 16" collimation error! I turned the camera around to make sure that the error that I'm seeing is purely the scope and not the camera. Moved it slowly down to 4". Then it changed direction. And then it got funny: for the other 2 collimation screws, the star moved away from the screw when I tightened it. But for the third, it moved towards the screw when I tightened it. That certainly explains the difficulties that I had to improve collimation earlier. After I figured this out, I could bring collimation below 1" (then it changed direction from picture to picture).
Also, at this point the image had no tilt at all!
Now I could have slowly added equipment to it.
... but instead, I'd rather focus on Hyperstar imaging. I know now that the camera is completely orthogonal, so I can use it for collimation of the Hyperstar lens. So, reconfigure the entire scope (cables, secondary mirror, hyperstar lens).
Collimating the Hyperstar lens turns out to be a major pain in the ...
I have to use multi-star collimation - because of the wide field of the Hyperstar lens, I couldn't find a brigh enough start that didn't have other stars in its vicinity. Furthermore, to defocus a start enough for out-of focus collimation with CCDInspector is outside of the range of my focuser!
Because of stray light and the moon light, I have to use a shield on the scope to get correct collimation. But that means that I have to take the damn shield off whenever I need to adjust the Hyperstar lens, then put it back on.
This is the initial state:
Tilt and quite a large collimation error.
This is the final result:
Almost no collimation: good!
Almost no image tile: good!
But look at that curvature!!! I have absolutely no idea what to do about that...
Sunday, October 6, 2013
CalStar - 3rd night
After last night, I had high hopes to make good progress on imaging. First to finish imaging the Fireworks Galaxy. And then start imaging the Trifid of the North.
Setup went well. Starting taking the remaining images of the Fireworks Galaxy. Then I woke up in time to check if SGPro started imaging the Trifid. Looked good. Went to bed.
Next morning, I checked the images. Fireworks looked good. Luminance of Trifid looked good:

But the RGB all looked like this:

I guess, the battery that powered the imaging equipment and the laptop wasn't fully charged and the camera or the USB hub dropped pixels.
After something major went bad every night, I decided to call it quits and not stay for a fourth night. Also, I was really yearning for a warm bed!
Setup went well. Starting taking the remaining images of the Fireworks Galaxy. Then I woke up in time to check if SGPro started imaging the Trifid. Looked good. Went to bed.
Next morning, I checked the images. Fireworks looked good. Luminance of Trifid looked good:


I guess, the battery that powered the imaging equipment and the laptop wasn't fully charged and the camera or the USB hub dropped pixels.
After something major went bad every night, I decided to call it quits and not stay for a fourth night. Also, I was really yearning for a warm bed!
Saturday, October 5, 2013
CalStar - 2nd night
I spent the day trying to figure out what is wrong with my scope:
- I checked the flatness of the image - minimum tilt
- Cleaned the OAG prism
- Cleaned the corrector plate (very careful - there was a lot of sand and dust on it)
- Took exact latitude and longitude from the GPS system
- Checked all mechanical connections on the mount
Then at the beginning of the night, I continued to focus on improving the guiding (if I can't figure it out, I could go home).
I used AlignMaster for polar alignment again. I did 3 iterations and in the last iteration, the correction was minimal. Verified collumation - good (below 1").
Mark Scrivener and John Wainwright gave me a couple of good tips:
- Use the ASCOM driver for guiding - not through the RJ45 cable
- Disable guiding commands in PHD and just see where the guidestar moves
- Guide (or test) with the main camera - not the Lodestar. This rules out any issues with the OAG or such.
I calibrated PHD near the equator and ran it without guiding. It showed an almost perfect polar alignment - even after 10 minutes, the trendline looked completely horizontal. And the RA trendline went up very straight and smooth. So, the scope is fine, polar alignment is great. Repeated the same with the lodestar - same result. So, the OAG is fine too.
When I was almost ready to declare defeat, one of my neighbours came over to me and asked what was wrong. I walked him through everything. He then wanted to look at my PHD parameters. And he pointed out that my "Max Duration" was too low (I had it at 200). He recommended to set it to 800...
... and voila! Suddenly guiding errors dropped below 0.2 arsec!!! AAAAAHHHHHHH!
I then started guiding again. Watched it for a little - looked really good.
I woke up at 1am to check if SGPro started imaging the 2nd target - worked!!!
And then in the morning, I found out that at 2am guiding completely stopped!!!!!! NOOOOOOOOOO!!!
But the images from the first target were now MUCH better:
This is much better. Although for a 1x1 binned luminance subframe it's still a little blurry.
Friday, October 4, 2013
CalStar - 1st Night
I arrived at 4pm, setup my tent and my scope - all without a hitch. Yes - all ready to get going once it turned dark.
When I connected the Mach1 scope, I couldn't remember which location number was CalStar - it would be awesome if I could assign names... Next surprise: the Mach1 mount can't run off the same battery as the rest of my equipment! The motors sounded horrible and slews stopped half way there. So, I needed to use one battery for the mount. And the other battery for the rest of the equipment. Had to improvise to connect the second splitter to the second battery. And I hope I can recharge both batteries enough tomorrow.
Next, I did a rough polar alignment with the RAPAS, star sync and then wanted to do a more accurate polar alignment with PEMPro. But it complained that my camera was rotated in a bad way and that it couldn't do it. No idea where that came from.
So, I used AlignMaster instead. Not sure how exact this was as I needed exact longitude and latitude of the place.
Next, I wanted to work on collimation with CCDInspector. I could improve it, but at some point the results didn't make sense again. I think I got it somewhere below 1" - good!
And finally PHD...
... complete desaster! I have no idea what was going on with that. I could barely get the accuracy below 0.6" and very erratic. In San Jose in my backyard, I could get it below 0.4". At some point - it was almost midnight by now- I got too tired and too irritated to continue trying things out. I setup the scope to start imaging anyway. Maybe guiding would improve later that night.
I got up in the middle of the night when SGPro had to slew to the next object. And PHD could not resume - didn't find a guide start. I checked everything. Finally I took new darks for the autoguider (this time from a REALLY dark side) - and that fixed it! Guiding by now was a little better - but not by a lot.
Next morning, I checked the images - they were all very bad.
This is a 1x1 binned luminance subframe :-(
Clearly the guiding is not suitable. Need to figure out what to do about PHD. I compared my guiding graphs from last night to guiding graphs at home - they don't look that much worse. But much more erratic.
Now I had to use my solar panels for the first time. Needed to cut some cables and make some connectors and got one battery to recharge. I hope that the other (the one that powered the mount) doesn't need recharging.
Oh, and: IT WAS REALLY COLD! I do remember that I was camping once in England when it froze and snowed. But last night felt worse. I guess after 20+ years I need a new sleeping bag :-S
When I connected the Mach1 scope, I couldn't remember which location number was CalStar - it would be awesome if I could assign names... Next surprise: the Mach1 mount can't run off the same battery as the rest of my equipment! The motors sounded horrible and slews stopped half way there. So, I needed to use one battery for the mount. And the other battery for the rest of the equipment. Had to improvise to connect the second splitter to the second battery. And I hope I can recharge both batteries enough tomorrow.
Next, I did a rough polar alignment with the RAPAS, star sync and then wanted to do a more accurate polar alignment with PEMPro. But it complained that my camera was rotated in a bad way and that it couldn't do it. No idea where that came from.
So, I used AlignMaster instead. Not sure how exact this was as I needed exact longitude and latitude of the place.
Next, I wanted to work on collimation with CCDInspector. I could improve it, but at some point the results didn't make sense again. I think I got it somewhere below 1" - good!
And finally PHD...
... complete desaster! I have no idea what was going on with that. I could barely get the accuracy below 0.6" and very erratic. In San Jose in my backyard, I could get it below 0.4". At some point - it was almost midnight by now- I got too tired and too irritated to continue trying things out. I setup the scope to start imaging anyway. Maybe guiding would improve later that night.
I got up in the middle of the night when SGPro had to slew to the next object. And PHD could not resume - didn't find a guide start. I checked everything. Finally I took new darks for the autoguider (this time from a REALLY dark side) - and that fixed it! Guiding by now was a little better - but not by a lot.
Next morning, I checked the images - they were all very bad.
This is a 1x1 binned luminance subframe :-(
Clearly the guiding is not suitable. Need to figure out what to do about PHD. I compared my guiding graphs from last night to guiding graphs at home - they don't look that much worse. But much more erratic.
Now I had to use my solar panels for the first time. Needed to cut some cables and make some connectors and got one battery to recharge. I hope that the other (the one that powered the mount) doesn't need recharging.
Oh, and: IT WAS REALLY COLD! I do remember that I was camping once in England when it froze and snowed. But last night felt worse. I guess after 20+ years I need a new sleeping bag :-S
Subscribe to: